Code: 9080

Description: LED fault detection
When the power supply is turned on, the peak value of LED is 80hex or less.
Causes: Defective connector cable or poor contact in the connector.
Defective CIS
Defective DPSHD PWB.
Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. CIS and DPSHD PWB (YC1) DPSHD PWB (YC1) and DP main PWB (YC10)
Defective CIS. Replace CIS and check for correct operation.
Defective DPSHD PWB. Replace the DPSHD PWB and check for correct operation.

Code: 9100

Description: Coin vender control PWB error
Communication error has been detected at the coin mec of the coin vender control PWB.
Causes: Defective coin vender control PWB.
Remedy: Replace the coin mec.

Code: 9110

Description: Coin vender error
Communication error has been detected in connection with the coin mec and the rejector.
Causes: Rejector installed incorrectly.
Defective rejector.
Remedy: Rejector installed incorrectly. Check the rejector is properly installed and, if not, perform the corrective action.
Defective rejector. Replace the rejector.

Code: 9120

Description: Sensor error in coin vender change (Yen 10)
Change is empty despite change is enough.
Causes: Coin jam in the change tube
Poor contact in the connector.
Defective change empty sensor.
Defective coin vender control PWB.
Remedy: Coin jam in the change tube Check visually and remedy.
Poor contact in the connector. Check if the change empty sensor is intact.
Defective change empty sensor. Replace the coin mec.
Defective coin vender control PWB. Replace the coin mec.

Code: 9130

Description: Sensor error in coin vender change (Yen 50)
Change is empty despite change is enough.
Causes: Coin jam in the change tube
Poor contact in the connector.
Defective change empty sensor.
Defective coin vender control PWB.
Remedy: Coin jam in the change tube Check visually and remedy.
Poor contact in the connector. Check if the change empty sensor is intact.
Defective change empty sensor. Replace the coin mec.
Defective coin vender control PWB. Replace the coin mec.

Code: 9140

Description: Sensor error in coin vender change (Yen 100)
Change is empty despite change is enough.
Causes: Coin jam in the change tube
Poor contact in the connector.
Defective change empty sensor.
Defective coin vender control PWB.
Remedy: Coin jam in the change tube Check visually and remedy.
Poor contact in the connector. Check if the change empty sensor is intact.
Defective change empty sensor. Replace the coin mec.
Defective coin vender control PWB. Replace the coin mec.

Code: 9150

Description: Sensor error in coin vender change (Yen 500)
Change is empty despite change is enough.
Causes: Coin jam in the change tube
Poor contact in the connector.
Defective change empty sensor.
Defective coin vender control PWB.
Remedy: Coin jam in the change tube Check visually and remedy.
Poor contact in the connector. Check if the change empty sensor is intact.
Defective change empty sensor. Replace the coin mec.
Defective coin vender control PWB. Replace the coin mec.

Code: 9160

Description: Coin vender pay-out error
Coin is paid out despite the pay-out motor is determined not active.
Causes: Defective pay-out motor.
Remedy: Replace the coin mec.