Description: DP EEPROM error Mismatch of reading data from two locations occurs 3 times successively. Mismatch between writing data and reading data occurs 3 times successively.
Causes: DP main PWB. Device damage of EEPROM.
Remedy: DP main PWB 1. Execute U906 Separating Operation Release. 2. Confirm that the EEPROM has been properly installed. 3. Replace the DP main PWB Device damage of EEPROM Contact the Service Support.
Description: Communication error between DP and SHD A communication error is detected.
Causes: DP SHD PWB.
Remedy: DP SHD PWB 1. Execute U906 Separating Operation Release. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. DP SHD PWB (YC1) and DP main PWB (YC10) 3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4. Replace the DP SHD PWB.
Description: LED fault detection A block is existent below a peak which was obtained by activating the LEDs in the four CIS blocks at power on, which is less than 80hex.
Causes: DP CIS. DP SHD PWBS.
Remedy: DP CIS 1. Execute CIS automatic original document alignment by U411. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. CIS and DP SHD PWB (YC2) DP SHD PWB (YC1) and DP main PWB (YC10) 3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4. Replace the CIS and execute U411. DP SHD PWB Replace the DP SHD PWB.
Description: Sensor error in coin vender change (Yen 10) Change is empty despite change is enough.
Causes: Coin jam in the change tube. Contact in the connector. Change empty sensor. Coin vender control PWB.
Remedy: Coin jam in the change tube Check visually and remedy. Contact in the connector Check the connection of the empty change sensor. Change empty sensor Replace the coin mec. Coin vender control PWB Replace the coin mec.
Description: Sensor error in coin vender change (Yen 50) Change is empty despite change is enough.
Causes: Coin jam in the change tube. Contact in the connector. Change empty sensor. Coin vender control PWB.
Remedy: Coin jam in the change tube Check visually and remedy. Contact in the connector Check the connection of the empty change sensor. Change empty sensor Replace the coin mec. Coin vender control PWB Replace the coin mec.
Description: Sensor error in coin vender change (Yen 100) Change is empty despite change is enough.
Causes: Coin jam in the change tube. Contact in the connector. Change empty sensor. Coin vender control PWB.
Remedy: Coin jam in the change tube Check visually and remedy. Contact in the connector Check the connection of the empty change sensor. Change empty sensor Replace the coin mec. Coin vender control PWB Replace the coin mec.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.