Code: 6710

Description: Fuser IH PWB CPU reset error
Watch doc timer has been overflowed.
Causes: Defective connector cable or poor contact in the connector.
Defective fuser IH PWB
Defective engine PWB.
Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Fuser IH PWB (YC4) and engine PWB (YC26)
Defective fuser IH PWB. Replace the fuser IH PWB and check for correct operation.
Defective engine PWB. Replace the engine PWB and check for correct operation.

Code: 6720

Description: Fuser IH belt rotation error
A belt rotating pulse is not received for 1 second.
Causes: Defective connector cable or poor contact in the connector.
Defective fuser belt sensor.
Defective engine PWB
Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Fuser unit and engine PWB (YC26)
Defective fuser belt sensor. Replace the fuser belt sensor.
Defective engine PWB. Replace the engine PWB and check for correct operation.

Code: 6730

Description: Abnormally high fuser IH PWB temperature 1
The input detect temperature is greater than 105°C/221 °F.
Causes: Defective connector cable or poor contact in the connector.
Defective fuser IH PWB.
Defective engine PWB.
Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Fuser IH PWB (YC4) and engine PWB (YC26)
Defective fuser IH PWB. Replace the fuser IH PWB and check for correct operation.
Defective engine PWB. Replace the engine PWB and check for correct operation.

Code: 6740

Description: Abnormally high fuser IH PWB temperature 2
The input detect temperature is greater than 105°C/221 °F.
Causes: Defective connector cable or poor contact in the connector.
Defective fuser IH PWB.
Defective engine PWB.
Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Fuser IH PWB (YC4) and engine PWB (YC26)
Defective fuser IH PWB. Replace the fuser IH PWB and check for correct operation.
Defective engine PWB. Replace the engine PWB and check for correct operation.

Code: 6750

Description: Fuser IH output over-current error
The output current is greater than 75A for 10 ms in succession.
Causes: Defective connector cable or poor contact in the connector.
Defective fuser IH PWB.
Defective engine PWB.
Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Fuser IH PWB (YC4) and engine PWB (YC26)
Defective fuser IH PWB. Replace the fuser IH PWB and check for correct operation.
Defective engine PWB. Replace the engine PWB and check for correct operation.

Code: 6760

Description: Fuser IH input over-current error
The input current is greater than 20A for 100 ms in succession.
Causes: Defective connector cable or poor contact in the connector.
Defective fuser IH PWB.
Defective engine PWB.
Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Fuser IH PWB (YC4) and engine PWB (YC26)
Defective fuser IH PWB. Replace the fuser IH PWB and check for correct operation.
Defective engine PWB. Replace the engine PWB and check for correct operation.

Code: 6770

Description: Fuser IH low electric power error
The preset power is less than 0.6 times of it for 120 ms in succession.
Causes: Defective connector cable or poor contact in the connector.
Defective fuser IH PWB
Defective engine PWB.
Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Fuser IH PWB (YC4) and engine PWB (YC26)
Defective fuser IH PWB. Replace the fuser IH PWB and check for correct operation.
Defective engine PWB. Replace the engine PWB and check for correct operation.

Code: 6780

Description: Fuser IH input over-voltage error
The input voltage is greater than 140V for 200 ms in succession.
Causes: Defective connector cable or poor contact in the connector.
Defective fuser IH PWB.
Defective engine PWB.
Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Fuser IH PWB (YC4) and engine PWB (YC26)
Defective fuser IH PWB. Replace the fuser IH PWB and check for correct operation.
Defective engine PWB. Replace the engine PWB and check for correct operation.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie