Description: Drum motor K sub sensor error No signal is input to the sensor for 1.5 s continuously.
Causes: Poor contact in the connector terminals. Defective drum motor K. Defective PWB.
Remedy: Poor contact in the connector terminals. Check the connection of connector YC8 on the motor control PWB and the connector of the drum motor K, and the continuity across the connector terminals. Repair or replace if necessary. Defective drum motor K. Replace the drum motor K. Defective PWB. Replace the motor control PWB or engine PWB and check for correct operation.
Description: Drum motor C sub sensor error No signal is input to the sensor for 1.5 s continuously.
Causes: Poor contact in the connector terminals. Defective drum motor C Defective PWB.
Remedy: Poor contact in the connector terminals. Check the connection of connector YC6 on the motor control PWB and the connector of the drum motor C, and the continuity across the connector terminals. Repair or replace if necessary. Defective drum motor C. Replace the drum motor C. Defective PWB. Replace the motor control PWB or engine PWB and check for correct operation.
Description: Drum motor M sub sensor error No signal is input to the sensor for 1.5 s continuously.
Causes: Poor contact in the connector terminals. Defective drum motor M. Defective PWB.
Remedy: Poor contact in the connector terminals. Check the connection of connector YC5 on the motor control PWB and the connector of the drum motor M, and the continuity across the connector terminals. Repair or replace if necessary. Defective drum motor M. Replace the drum motor M. Defective PWB. Replace the motor control PWB or engine PWB and check for correct operation.
Description: Drum motor Y sub sensor error No signal is input to the sensor for 1.5 s continuously.
Causes: Poor contact in the connector terminals. Defective drum motor Y. Defective PWB.
Remedy: Poor contact in the connector terminals. Check the connection of connector YC7 on the motor control PWB and the connector of the drum motor Y, and the continuity across the connector terminals. Repair or replace if necessary. Defective drum motor Y. Replace the drum motor Y. Defective PWB. Replace the motor control PWB or engine PWB and check for correct operation.
Description: Drum motor K device sensor error The device alarm signal is input.
Causes: Poor contact in the connector terminals Defective drum motor K. Defective PWB.
Remedy: Poor contact in the connector terminals. Check the connection of connector YC8 on the motor control PWB and the connector of the drum motor K, and the continuity across the connector terminals. Repair or replace if necessary. Defective drum motor K. Replace the drum motor K. Defective PWB. Replace the motor control PWB or engine PWB and check for correct operation.
Description: Drum motor C device error The device alarm signal is input.
Causes: Poor contact in the connector terminals. Defective drum motor C. Defective PWB
Remedy: Poor contact in the connector terminals. Check the connection of connector YC6 on the motor control PWB and the connector of the drum motor C, and the continuity across the connector terminals. Repair or replace if necessary. Defective drum motor C. Replace the drum motor C. Defective PWB. Replace the motor control PWB or engine PWB and check for correct operation.
Description: Drum motor M device error The device alarm signal is input.
Causes: Poor contact in the connector terminals. Defective drum motor M. Defective PWB.
Remedy: Poor contact in the connector terminals. Check the connection of connector YC5 on the motor control PWB and the connector of the drum motor M, and the continuity across the connector terminals. Repair or replace if necessary. Defective drum motor M. Replace the drum motor M. Defective PWB. Replace the motor control PWB or engine PWB and check for correct operation.
Description: Drum motor Y device error The device alarm signal is input.
Causes: Poor contact in the connector terminals. Defective drum motor Y. Defective PWB.
Remedy: Poor contact in the connector terminals. Check the connection of connector YC7 on the motor control PWB and the connector of the drum motor Y, and the continuity across the connector terminals. Repair or replace if necessary. Defective drum motor Y. Replace the drum motor Y. Defective PWB. Replace the motor control PWB or engine PWB and check for correct operation.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.