Code :
  • Code: 1020
  • Description: Lift motor 2 error
    After cassette 2 is inserted, lift sensor 2 does not turn on within 12 s. This error is detected 4 times successively. The lock signal of the motor is detected continuously for 1 s. This error is detected 4 times successively.
  • Causes: Cassette lift base elevating mechanism. Lift motor 2. Lift sensor 2. Feed PWB 2. Engine PWB.
  • Remedy: Cassette lift base elevating mechanism Check that the cassette base can be manipulated smoothly, if not, repair or replace.
    Lift motor 2 1. Check that the cassette base has been ascended. 2. Check the drive gear can rotate or they are not unusually loaded and, if necessary, replace. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Lift motor 2 and Feed PWB 2 (YC3) Feed PWB 2 (YC1) and Engine PWB (YC4) 4. If the wiring is disconnected, shorted or grounded, replace the wiring. 5. Replace the lift motor 2.
    Lift sensor 2 1. Check that the sensor is correctly positioned. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Lift sensor 2 and Feed PWB 2 (YC8) Feed PWB 2 (YC1) and Engine PWB (YC4) 3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4. Replace the lift sensor2.
    Feed PWB 2 Replace the Feed PWB 2.
    Engine PWB 1. Check the engine software and upgrade to the latest, if necessary. 2. Replace the engine PWB.
  • Code: 1030
  • Description: PF lift motor 1 error (paper feeder)
    After cassette 3 is inserted, PF lift sensor 1 does not turn on within 12 s. This error is detected 5 times successively. During driving the motor, the lift overcurrent protective monitor signal is detected for 1 s or more 5 times successively. However, the first 1 s after motor is turned on is excluded from detection.
  • Causes: PF Lift motor 1. PF Lift sensor 1. PF main PWB.
  • Remedy: Cassette lift base elevating mechanism Check that the cassette base can be manipulated smoothly, if not, repair or replace.
    PF Lift motor 1 1. Check that the cassette base has been ascended. 2. Check the drive gear can rotate or they are not unusually loaded and, if necessary, replace. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. PF Lift motor 1 and main PWB (YC7) 4. If the wiring is disconnected, shorted or grounded, replace the wiring. 5. PFReplace the lift motor 1.
    PF Lift sensor 1 1. Check that the sensor is correctly positioned. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. PF Lift sensor 1 and PF main PWB (YC7) 3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4. Replace the lift sensor 1.
    PF main PWB Replace the PF main PWB (Refer to the service manual for the paper feeder).
  • Code: 1040
  • Description: PF lift motor 2 error (paper feeder)
    After cassette 4 is inserted, PF lift sensor 2 does not turn on within 12 s. This error is detected 5 times successively. During driving the motor, the lift overcurrent protective monitor signal is detected for 1 s or more 5 times successively. However, the first 1 s after motor is turned on is excluded from detection.
  • Causes: Cassette lift base elevating mechanism. PF Lift motor 2. PF Lift sensor 2. PF main PWB.
  • Remedy: Cassette lift base elevating mechanism Check that the cassette base can be manipulated smoothly, if not, repair or replace.
    PF Lift motor 2 1. Check that the cassette base has been ascended. 2. Check the drive gear can rotate or they are not unusually loaded and, if necessary, replace. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. PF Lift motor 2 and PF main PWB (YC7) 4. If the wiring is disconnected, shorted or grounded, replace the wiring. 5. Replace the PF Lift motor2.
    PF Lift sensor 2 1. Check that the sensor is correctly positioned. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. PF Lift sensor 2 and PF main PWB (YC7) 3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4. Replace the PF Lift sensor 2.
    PF main PWB Replace the PF main PWB (Refer to the service manual for the paper feeder).
  • Code: 1100
  • Description: PF lift motor 1 error (large capacity feeder)
    After cassette 3 is inserted, PF lift sensor 1 does not turn on within 23 s. This error is detected 5 times successively. (Time to detect is 2 seconds at the second time and later.) During driving the motor, the lift overcurrent protective monitor signal is detected for 200 ms or more 5 times successively. However, the first 1 s after PF lift motor 1 is turned on is excluded from detection
  • Causes: Paper feeder lift base elevating mechanism. PF Lift motor1. PF Lift sensor1. PF main PWB.
  • Remedy: Paper feeder lift base elevating mechanism Check that the cassette base can be manipulated smoothly, if not, repair or replace.
    PF Lift motor1 1. Check that the cassette base has been ascended. 2. Check the drive gear can rotate or they are not unusually loaded and, if necessary, replace. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. PF Lift motor 1 and PF main PWB (YC7) 4. If the wiring is disconnected, shorted or grounded, replace the wiring. 5. Replace the PF lift motor1.
    PF Lift sensor1 1. Check that the sensor is correctly positioned. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. PF Lift sensor 1 and PF main PWB (YC5) 3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4. Replace the PF lift sensor1.
    PF main PWB Replace the PF main PWB (Refer to the service manual for the paper feeder).
  • Code: 1110
  • Description: PF lift motor 2 error (large capacity feeder)
    After cassette 4 is inserted, PF lift sensor 2 does not turn on within 23 s. This error is detected 5 times successively. (Time to detect is 2 seconds at the second time and later.) During driving the motor, the lift overcurrent protective monitor signal is detected for 200 ms or more 5 times successively. However, the first 1 s after PF lift motor 2 is turned on is excluded from detection
  • Causes: Paper feeder lift base elevating mechanism. PF Lift motor 2. PF Lift sensor2. PF main PWB.
  • Remedy: Paper feeder lift base elevating mechanism Check that the cassette base can be manipulated smoothly, if not, repair or replace.
    PF Lift motor 2 1. Check that the cassette base has been ascended. 2. Check the drive gear can rotate or they are not unusually loaded and, if necessary, replace. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. PF Lift motor 2 and PF main PWB (YC7) 4. If the wiring is disconnected, shorted or grounded, replace the wiring. 5. Replace the PF Lift motor2.
    PF Lift sensor2 1. Check that the sensor is correctly positioned. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. PF Lift sensor 2 and PF main PWB (YC4) 3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4. Replace the PF Lift sensor 2.
    PF main PWB Replace the PF main PWB (Refer to the service manual for the paper feeder).
  • Code: 1140
  • Description: SD lift motor error (side deck)
    After cassette 5 is inserted, SD lift sensor does not turn on within 30 s. The lock signal of the motor is detected continuously for 200 ms.
  • Causes: Paper feeder lift base elevating mechanism. SD Lift motor. SD Lift sensor. SD main PWB.
  • Remedy: Paper feeder lift base elevating mechanism Check that the cassette base can be manipulated smoothly, if not, repair or replace.
    SD Lift motor 1. Check that the cassette base has been ascended. 2. Check the drive gear can rotate or they are not unusually loaded and, if necessary, replace. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. SD Lift motor and SD main PWB (YC8) 4. If the wiring is disconnected, shorted or grounded, replace the wiring. 5. Replace the SD Lift motor.
    SD Lift sensor 1. Check that the sensor is correctly positioned. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. SD Lift sensor and SD main PWB (YC5) 3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4. Replace the SD Lift sensor.
    SD main PWB Replace the SD main PWB (Refer to the service manual for the paper feeder).
  • Code: 1400
  • Description: Rotary guide motor error
    The guide sensor is not detected to be on at the home position detection with the rotary guide for three times in a row.
  • Causes: Rotary guide motor. BR PWB.
  • Remedy: Rotary guide motor 1. Check the rotary guide and drive gear can rotate or they are not unusually loaded and, if necessary, replace. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Rotary guide motor and BR PWB (YC5) 3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4. Replace the rotary guide motor.
    BR PWB Replace the BR PWB.
  • Code: 1410
  • Description: Rotary de-curler error
    If the de-curler won’t turn On/ Off despite it has been activated for 400 steps during waiting for the de-curler sensor to be On/Off three times in a row.
  • Causes: Rotary de-curler motor. BR PWB.
  • Remedy: Rotary de-curler motor 1. Check the rotary de-curler and drive gear can rotate or they are not unusually loaded and, if necessary, replace. 2. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Rotary de-curler motor and BR PWB (YC5) 3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4. Replace the rotary de-curler motor.
    BR PWB Replace the BR PWB.