Description: DP multi feed sensor communication error A communication error is detected 3 times in succession.
Causes: Defective connector cable or poor contact in the connector. Defective PWB.
Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. DP main PWB (YC1) and ISC PWB (YC12) ISC PWB (YC3) and main PWB (YC11) Defective PWB. Replace the DP main PWB or the ISC PWB and check for correct operation.
Code: 9210
Description: DP multi feed sensor error The DP multi feed sensor has signaled the presence of paper for 10 ms continuously.
Causes: Defective connector cable or poor contact in the connector. Defective DP multi feed sensor. Defective DP main PWB.
Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. DP multi feed sensor and DP main PWB (YC11) Defective DP multi feed sensor. Replace the DP multi feed sensor. Defective DP main PWB. Replace the DP main PWB and check for correct operation.
Code: 9220
Description: DP multi feed sensor backup error When writing the data, read and write data does not match 3 times in succession.
Causes: Defective connector cable or poor contact in the connector. Defective DP multi feed sensor. Defective DP main PWB.
Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. DP multi feed sensor and DP main PWB (YC11) Defective DP multi feed sensor. Replace the DP multi feed sensor. Defective DP main PWB. Replace the DP main PWB and check for correct operation.
Code: 9500, 9510, 9520
Description: Contact the Service Administrative Division.
Causes:
Remedy: Contact the Service Administrative Division.
Code: F000
Description: Communication error between main PWB and operation PWB
Causes: Defective main PWB. Defective operation PWB.
Remedy: Defective main PWB. Turn the main power switch off/on to restart the machine. If the error is not resolved, replace main PWB. Defective operation PWB. Replace the operation PWB and check for correct operation.
Code: F010
Description: Main PWB checksum error
Causes: Defective main PWB.
Remedy: Turn the main power switch off/on to restart the machine. If the error is not resolved, replace main PWB.
Code: F040
Description: Communication error between main PWB and print engine
Causes: Defective main PWB. Defective engine PWB.
Remedy: Defective main PWB. Turn the main power switch off/on to restart the machine. If the error is not resolved, replace main PWB. Defective engine PWB. Replace the engine PWB and check for correct operation.
Code: F041
Description: Communication error between main PWB and scanner engine
Causes: Defective main PWB. Defective ISC PWB.
Remedy: Defective main PWB. Turn the main power switch off/on to restart the machine. If the error is not resolved, replace main PWB. Defective ISC PWB. Replace the ISC PWB and check for correct operation.