Description: Communication error between System-CPU and Scanner-CPU
Remedy: (1) Check if the harness connecting the IMG board and SLG board is disconnected or open circuited. (2) Check the version of the system ROM on the SYS board. (3) Check the version of the scanner ROM version on the SLG board. (4) Replace the SYS board. (5) Replace the SLG board.
Code: F111
Description: Scanner response abnormality
Remedy: (1) Check if the harness connecting the IMG board and SLG board is disconnected or open circuited. (2) Check the version of the system ROM on the SYS board. (3) Check the version of the scanner ROM version on the SLG board. (4) Replace the SYS board. (5) Replace the SLG board.
Code: F120
Description: Database abnormality: Database is not operating normally.
Remedy: (1) Check that no jobs remain and rebuild the databases. (Perform 08-684.) (2) If the error is not recovered, initialize the HDD. (Key in “2” at 08-690.) Notes: • If you rebuild the databases with a job remaining, delete it after finishing. • When “Rebuilding all databases (08-684)” is performed, all data in the Address Book and Mailbox are deleted. If you back up the data in advance, they will be recovered by restoring them after rebuilding the database.
Code: F130
Description: Invalid MAC address
Remedy: Replace the SYS board.
Code: F200
Description: Data Overwrite option (GP-1070) disabled
Remedy: Perform firmware installation (all firmware: OS, HDD, SYS, PFC Firmware, Engine Main Firmware, and Scanner Firmware) with the USB media. * When the function of the Data Overwrite option (GP-1070) is deleted from the equipment, the service call “F200” occurs.
Code: F350
Description: SLG board abnormality
Remedy: (1) Check if the conductor pattern on the SLG board is short circuited or open circuited. (2) If there is no problem found in the check (1) above, check the combination of the firmware version of the system ROM, engine ROM and scanner ROM. Reinstall the scanner ROM firmware. (3) If an error occurs after step (2) above has been performed, replace the SLG board.
Code: F400
Description: SYS board cooling fan abnormality
Remedy: (1) Check if the fan is rotating properly. (2) If not, check if any foreign object is adhered. (3) Is the connector CN126 of the SYS board connected securely? (4) Replace the SYS board cooling fan. (5) Replace the SYS board.