Mã lỗi Lexmark C510 — Trang 5/8
Description: NVRAM chip failure
Remedy:
Indicates engine board NVRAM failed. Replace engine controller board.
Description: NVRAM CRC failure
Remedy:
Indicates the operator panel failed CRC check. Replace the operator panel cable.
Description: Code CRC
Remedy:
Indicates that on-board NAND flash located on RIP board has failed CRC check. Replace RIP board
Description: Code ECC
Remedy:
Indicates that on-board NAND flash located on RIP board has failed CRC check.
Description: Processor failure
Remedy:
Indicates a problem with RIP board processor.
Description: ASIC failure
Remedy:
Indicates a problem with RIP board ASIC. Replace RIP board
Description: NAND failure
Remedy:
Indicates that on-board NAND flash located on RIP board has failed. Replace RIP board.
Description: SRAM failure
Remedy:
Indicates a problem with RIP board SRAM. Replace RIP board.