Description: RAM Memory Error There is an error in the memory installed in the memory option slot 1 on the system board. If another memory option is available, switch the memory options to isolate the problem.
Remedy: If you do not have a spare memory option to switch, then replace the memory installed. If this does not fix the problem, replace the system board.
Description: RAM Memory Error There is an error in the memory installed in the memory option slot 2 on the system board. If another memory option is available, switch the memory options to isolate the problem. If you do not have a spare memory option to switch, then replace the memory installed.
Remedy: If this does not fix the problem, replace the system board
Description: RAM Memory Error There is an error in the memory installed in the memory option slot 3 on the system board. If another memory option is available, switch the memory options to isolate the problem.
Remedy: If you do not have a spare memory option to switch, then replace the memory installed. If this does not fix the problem, replace the system boar
Remedy: Download emulation CRC failure has occurred. The following actions may be taken: 1. Disable the Download Emulation. 2. Program the download emulation into the code overlay SIMM again. 3. If the problem is not resolved, replace the code overlay SIMM and download emulation again.
Description: Standard Network or Network Card x Unrecognizable network Errors 975 through 979 indicate a failure with the standard network port located on the system board or a network card in the specified slot x, x=1, 2 or 3
Remedy: Unrecoverable software or error in network for network card x. If unable to clear the error message, check the following: • If installed, check network card for correct installation. • If correctly installed, replace the network card. • If a network card is not installed, replace the system board.
Remedy: Bad checksum while programming Standard Network or Network Card x port. Check the following: • Make sure you have downloaded the code in binary mode, not ASCII. • Reprogram the Network card. • If the problem persists, and if installed, check the network card for correct installation. • If correctly installed, replace the network card. • If a network card is not installed, replace the system board
Remedy: Flash parts failed while programming the Standard Network or Network Card x port. Check the following: • If installed, check the network card for correct installation. • If correctly installed, replace the network card. • If a network card is not installed, replace the system board.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.