Remedy: The Code ROM or NAND flash failed the Cyclic Redundancy Check (CRC) check or the NAND experienced an uncorrectible multi-bit failure. “<loc>” indicates the source of the failure and has one of the following values: • CRC Failure: The source is a failing package indicated by Pn where “n” is the package number. This error could occur on a controller with ROM or NAND flash and could occur as a result of the CRC check done when the machine is powered on. The range of package numbers is from 0 to 15. • Error Correction Code (ECC) Failure: The source is a failing page indicated by Bn where “n” is the page number. This error occurs only if a multi-bit failure is detected during the ECC execution. Single bit failures will be corrected automatically and will not result in a service error. The range of page numbers is from 0 to 1023.
Description: 959.01 Service Invalid Firmware Controller verification failure of pensive boot code. 959.02 Service Invalid Firmware Failure to authenticate signature verification code. 959.03 Service Invalid Firmware Signature verification code failure to authenticate a code partition. 959.04 Service Invalid Firmware Jump to unverified address. 959.05 Service Invalid Firmware Unknown boot failure. 959.20 Service RIP board System hardware failure. 959.21 ServicRIP boarde RIP board System did not respond to command request. 959.22 Service RIP board Challenge secret failure. 959.23 Service RIP board System self test failure during initialization. 959.24 Service RIP board EEPROM retention error (write failure). 959.25 Service RIP board Insufficient device space during hardware programming. 959.26 Service RIP board Incremental counter reset exceeds maximum value. 959.27 Service RIP board Increment count failed due to maximum value limit. 959.28 Service RIP board Invalid SP memory configuration.