Các lỗi thường gặp

Code :
  • Code: 915.00
  • Description: Redrive motor encoder not detected failure The redrive motor encoder detection is lost during normal operation
  • Remedy: 1. Check all the connections on the duplex drive motor assembly. 2. Check all the connections on the system card assembly. 3. Replace the duplex drive motor assembly if problem remains.
  • Code: 915.01
  • Description: Redrive motor over speed failure The redrive motor does not rotate at the specified speed.
  • Remedy: 1. Check all the connections on the duplex drive motor assembly. 2. Check all the connections on the system card assembly. 3. Replace the duplex drive motor assembly if problem remains.
  • Code: 916.00
  • Description: Internal duplex drive motor encoder not detected failure The duplex drive motor encoder detection is lost during normal operation
  • Remedy: 1. Check all the connections on the duplex drive motor assembly. 2. Check all the connections on the system card assembly. 3. Replace the duplex drive motor assembly if problem remains.
  • Code: 916.01
  • Description: Internal duplex drive motor over speed failure The duplex drive motor does not rotate at the specified speed.
  • Remedy: 1. Check all the connections on the duplex drive motor assembly. 2. Check all the connections on the system card assembly. 3. Replace the duplex drive motor assembly if problem remains.
  • Code: 920.00
  • Description: Fuser under temperature Fuser type = 1 Fuser does not maintain proper operating temperature within steady state control.
  • Remedy: 1. Turn the machine off/on and ensure the fuser unit assembly is properly installed. 2. Ensure the proper voltage fuser is installed in the machine. 3. Replace the fuser unit assembly if problem remains
  • Code: 920.01
  • Description: Fuser warm-up failure Fuser type = 1 The fuser hot roll took too long to heat up after transitioning to new enhanced mode within standby control only.
  • Remedy: 1. Turn the machine off/on and ensure the fuser unit assembly is properly installed. 2. Ensure the proper voltage fuser is installed in the machine. 3. Replace the fuser unit assembly if problem remains.
  • Code: 920.02
  • Description: Fuser warm-up failure Fuser type = 1 The fuser hot roll fell to far below desired temperature while in standby control.
  • Remedy: 1. Turn the machine off/on and ensure the fuser unit assembly is properly installed. 2. Ensure the proper voltage fuser is installed in the machine. 3. Replace the fuser unit assembly if problem remains.
  • Code: 920.03
  • Description: Fuser warm-up failure Fuser type = 1 The fuser hot roll is too cool while checking for slope change in standby.
  • Remedy: 1. Turn the machine off/on and ensure the fuser unit assembly is properly installed. 2. Ensure the proper voltage fuser is installed in the machine. 3. Replace the fuser unit assembly if problem remains.