Remedy: • Order a replacement fuser immediately. When print quality is reduced, install the new fuser, following the instruction sheet that came with the replacement part. • Touch Continue to clear the message and continue printing.
Remedy: 1. Replace the waste toner bottle. For instructions on replacing the waste toner bottle, from the printer control panel touch More Information. 2. Touch Continue to clear the message and continue printing.
Remedy: Order a replacement waste toner bottle immediately. 1. Replace the waste toner bottle. For instructions on installing the waste toner bottle, from the printer control panel touch More Information. 2. Touch Continue to clear the message and continue printing.
Description: Service scanner failure Image pipeline ASIC failure The image pipeline for processing the data that comes from the scanner, prior to being printed, has failed.
Remedy: 1 Perform a POR. Does the error occur when the power is turned off/on? Go to step 2. Perform several print tests. If the problem remains, then go to step 2. 2 Turn the printer off for 60 seconds. Does the error occur when the power is turned off/on again? Replace the RIP card assembly. Go to “RIP PCBA removal”. Problem resolved 3 Perform a POR. Does the error occur when the power is turned off/on? Go to step 2. Perform several print tests. If the problem remains, then go to step 2.
Description: Service scanner failure Scanner communication failure Controller detected a communication failure. Communication timeout.
Remedy: 1 Check the scanner interface cable assembly connection between the RIP card assembly and the scanner unit assembly. Is the scanner interface cable assembly connected properly? Go to step 2. Replace the connection. 2 Check all connections of the scanner controller PCBA. Are the connections of the scanner controller card assembly connected properly? Go to step 3. Connect each connector of the scanner controller card assembly properly. 3 Perform a POR. Does the error remain when the power is turned off/on? Replace the scanner controller PCBA. Go to “Scanner controller PCBA removal”. Go to step 4. Problem resolved 4 Perform a POR. Does the error remain when the power is turned off/on again? Replace the RIP PCBA. Go to “RIP PCBA removal”. Problem resolved
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.