Description: •Command code other than MRL has been received.
Remedy: 1) Check the data received through HEX dump. 2) If error occurs at 1394 a. Check Time out of the transfer tool (RIP). b. Replace the I/F connection board with [E102154A] or later. c. Replace the 1394 board with a new one. d. Replace the main PCB with a new one. e. Supply power to the 1394 PCI board in the PC through the power cable.
Description: • Parameter that has not defined in MRL has been received.
Remedy: 1) Check the data received through HEX dump. 2) If error occurs at 1394 a. Check Time out of the transfer tool (RIP). b. Replace the I/F connection board with [E102154A] or later. c. Replace the 1394 board with a new one. d. Replace the main PCB with a new one. e. Supply power to the 1394 PCI board in the PC through the power cable.
Description: •A error occurred in communication between the main PCB and the interface board.
Remedy: 1) Replace the I/F PCB with a new one. 2) Replace the main PCB with a new one. 3) Replace the I/F connection board with a new one. 4) Supply power to the 1394 PCI board in the PC through the power cable.