Code: 34-0

Display: ***** ERROR 34 ***** DATA REMAIN
Description: Presence of Undrawn Data on Setting Change

Code: 4-0

Display: ***** ERROR 04 ***** F-ROM
Description: Error on Parameter ROM

Code: 40-0

Display: ***** ERROR 40 ***** MOTOR ALARM X
Description: X Motor Overloaded 1: Position Over 3: Position Counter Up

Code: 41-0

Display: ***** ERROR 41 ***** MOTOR ALARM Y
Description: Y Motor Overloaded 2: Position Over 4: Position Counter Up

Code: 42-0

Display: ***** ERROR 42 ***** X OVER CURRENT
Description: X-Motor Over-current 5: X Peak Current Over 7: X Av. Current Over

Code: 43-0

Display: ***** ERROR 43 ***** Y OVER CURRENT
Description: Y Motor Over-current 6: Y Peak Current Over 8: Y Ax. Current Over

Code: 45-0

Display: ***** ERROR 45 ***** CAPPING : SENSOR
Description: Error on Capping Control (Sensor Error)

Code: 45-1

Display: ***** ERROR 45 ***** CAPPING : PARAMETER
Description: Error on Capping Control (Parameter Error)