Description: Abnormal condition in PF motor (X-axis) during printer operation. Displayed if the difference between motor command value and feedback from encoder is large.
Code: E066
Display: E 066 error CR motor
Description: Abnormal condition in CR motor (Yaxis) during printer operation. Displayed if the difference between motor command value and feedback from encoder is large.
Code: E067
Display: E 067 error PF encoder
Description: Abnormal condition in media feed amount (Xaxis) during printer operation. Displayed if there is no feedback from encoder.
Code: E068
Display: E 068 error CR encoder
Description: Abnormal condition in head travel distance (Yaxis) during printer operation. Displayed if there is no feedback from encoder.
Code: E069
Display: E069 error PF timeout
Description: Time-out condition in media feed amount (Xaxis) during printer operation. Displayed if pressure roller does not reach the defined position.
Code: E070
Display: E 070 error CR timeout
Description: Time-out condition in head travel distance (Yaxis) during printer operation. Displayed if carriage does not reach the defined position.
Code: E071
Display: E071 error PF overcurrent
Description: Overload condition in PF motor (X-axis) during printer operation.