Description: An anomaly is detected in After heater system (Thermistor, Heater).
Code: E079
Display: E079 Err Board Commu
Description: An anomaly is detected in the serial communication between MAIN Board Assy and HEATER CONTROL Board Assy during printer operation.
Code: E081
Display: E081 Err CR Origin
Description: CR_HP cannot be detected.
Code: E082
Display: E082 Err Wiper Sns.
Description: An anomaly is detected in Wiper sensor.
Code: E085
Display: E085 Err Head Heat
Description: An anomaly is detected in Head driver.
Code: E087
Display: E087 Err H trans Th.
Description: An anomaly is detected in Head transistor.
Code: E090
Display: E090 Err Heater Volt
Description: Displayed when voltage exceeds the threshold level of 200V start up even though the printer was started with the voltage of 100V on HEATER CONTROL board Assy.
Code: E092
Display: E092 Err CR Overload
Description: An overload condition is detected in CR motor (Yaxis) during printer operation.