  • Code: E078
  • Display: E078 Err After Heat
  • Description: An anomaly is detected in After heater system (Thermistor, Heater).
  • Code: E079
  • Display: E079 Err Board Commu
  • Description: An anomaly is detected in the serial communication between MAIN Board Assy and HEATER CONTROL Board Assy during printer operation.
  • Code: E081
  • Display: E081 Err CR Origin
  • Description: CR_HP cannot be detected.
  • Code: E082
  • Display: E082 Err Wiper Sns.
  • Description: An anomaly is detected in Wiper sensor.
  • Code: E085
  • Display: E085 Err Head Heat
  • Description: An anomaly is detected in Head driver.
  • Code: E087
  • Display: E087 Err H trans Th.
  • Description: An anomaly is detected in Head transistor.
  • Code: E090
  • Display: E090 Err Heater Volt
  • Description: Displayed when voltage exceeds the threshold level of 200V start up even though the printer was started with the voltage of 100V on HEATER CONTROL board Assy.
  • Code: E092
  • Display: E092 Err CR Overload
  • Description: An overload condition is detected in CR motor (Yaxis) during printer operation.