Code: 143

Description: Drum Up/Down, Color: Black (Reserved)
Remedy:

Code: 163

Description: Toner Sensor Error, Color: Black
Remedy:

Code: 170

Description: Upper Thermistor, State: Short
Remedy: Turn the power off, then back on again. • Yes Is the thermistor open or shorted? Measure the resistance between thermistor contacts (heater contacts 120V/2Ω or 240V/7Ω, and thermistor contacts 200KΩ at room temperature) . • Yes Replace the fusing unit. • No Do the thermistor connector is connected to the main control board connector? • No Connect the thermistor connector property. • Yes Is the heater of the fusing unit turned on (when the heater is turned on, light is emitted)? • Yes Check the thermistor connector or replace the main control board or the fusing unit. • No Is the AC voltage being supplied to the connector for the heater of the power supply board? • No Replace the main control board or the power supply/sensor board. • Yes Check the heater connector cord and the heater connector for poor contact .

Code: 171

Description: Upper Thermistor, State: Open
Remedy: Turn the power off, then back on again. • Yes Is the thermistor open or shorted? Measure the resistance between thermistor contacts (heater contacts 120V/2Ω or 240V/7Ω, and thermistor contacts 200KΩ at room temperature) . • Yes Replace the fusing unit. • No Do the thermistor connector is connected to the main control board connector? • No Connect the thermistor connector property. • Yes Is the heater of the fusing unit turned on (when the heater is turned on, light is emitted)? • Yes Check the thermistor connector or replace the main control board or the fusing unit. • No Is the AC voltage being supplied to the connector for the heater of the power supply board? • No Replace the main control board or the power supply/sensor board. • Yes Check the heater connector cord and the heater connector for poor contact .

Code: 172

Description: Upper Heater Temp, State: High
Remedy: Turn the power off, then back on again. • Yes Is the thermistor open or shorted? Measure the resistance between thermistor contacts (heater contacts 120V/2Ω or 240V/7Ω, and thermistor contacts 200KΩ at room temperature) . • Yes Replace the fusing unit. • No Do the thermistor connector is connected to the main control board connector? • No Connect the thermistor connector property. • Yes Is the heater of the fusing unit turned on (when the heater is turned on, light is emitted)? • Yes Check the thermistor connector or replace the main control board or the fusing unit. • No Is the AC voltage being supplied to the connector for the heater of the power supply board? • No Replace the main control board or the power supply/sensor board. • Yes Check the heater connector cord and the heater connector for poor contact .

Code: 173

Description: Upper Heater Temp, State: Low
Remedy: Turn the power off, then back on again. • Yes Is the thermistor open or shorted? Measure the resistance between thermistor contacts (heater contacts 120V/2Ω or 240V/7Ω, and thermistor contacts 200KΩ at room temperature) . • Yes Replace the fusing unit. • No Do the thermistor connector is connected to the main control board connector? • No Connect the thermistor connector property. • Yes Is the heater of the fusing unit turned on (when the heater is turned on, light is emitted)? • Yes Check the thermistor connector or replace the main control board or the fusing unit. • No Is the AC voltage being supplied to the connector for the heater of the power supply board? • No Replace the main control board or the power supply/sensor board. • Yes Check the heater connector cord and the heater connector for poor contact .

Code: 179

Description: Fuser Mismatch (Reserved)
Remedy:

Code: 180

Description: I/F Error, Loc: Envelop feeder
Remedy: Is an option tray (High Capacity Second Paper Feeder or Power Envelope Feeder) being used? • Yes Is the cable between the main control board and the optional tray being connected properly? • No Connect the cable properly. • Yes Replace the main control board. • Has the problem been solved? • No Check the problem by following the High Capacity Second Paper Feeder maintenance manual of Appendix F. • Yes End • No Replace the main control board. • Has the problem been solved? • No Replace the power supply/sensor board. • Yes End