Các lỗi thường gặp

Code :
  • Code: 125
  • Description: Multi purpose tray home error (Reserved)
  • Remedy:
  • Code: 130
  • Description: LED Head Over Temperature
  • Remedy:
  • Code: 134
  • Description: LED Head Missing, Color: Black (Reserved)
  • Remedy:
  • Code: 143
  • Description: Drum Up/Down, Color: Black (Reserved)
  • Remedy:
  • Code: 163
  • Description: Toner Sensor Error, Color: Black
  • Remedy:
  • Code: 170
  • Description: Upper Thermistor, State: Short
  • Remedy: Turn the power off, then back on again. • Yes Is the thermistor open or shorted? Measure the resistance between thermistor contacts (heater contacts 120V/2Ω or 240V/7Ω, and thermistor contacts 200KΩ at room temperature) . • Yes Replace the fusing unit. • No Do the thermistor connector is connected to the high voltage/sensor board connector? • No Connect the thermistor connector property. • Yes Is the heater of the fusing unit turned on (when the heater is turned on, light is emitted)? • Yes Check the thermistor connector or replace the main control board or the fusing unit. • No Is the AC voltage being supplied to the connector for the heater of the power supply board? • No Replace the main control board or the power supply board. • Yes Check the heater connector cord and the heater connector for poor contact .
  • Code: 171
  • Description: Upper Thermistor, State: Open
  • Remedy: Turn the power off, then back on again. • Yes Is the thermistor open or shorted? Measure the resistance between thermistor contacts (heater contacts 120V/2Ω or 240V/7Ω, and thermistor contacts 200KΩ at room temperature) . • Yes Replace the fusing unit. • No Do the thermistor connector is connected to the high voltage/sensor board connector? • No Connect the thermistor connector property. • Yes Is the heater of the fusing unit turned on (when the heater is turned on, light is emitted)? • Yes Check the thermistor connector or replace the main control board or the fusing unit. • No Is the AC voltage being supplied to the connector for the heater of the power supply board? • No Replace the main control board or the power supply board. • Yes Check the heater connector cord and the heater connector for poor contact .
  • Code: 172
  • Description: Upper Heater Temp, State: High
  • Remedy: Turn the power off, then back on again. • Yes Is the thermistor open or shorted? Measure the resistance between thermistor contacts (heater contacts 120V/2Ω or 240V/7Ω, and thermistor contacts 200KΩ at room temperature) . • Yes Replace the fusing unit. • No Do the thermistor connector is connected to the high voltage/sensor board connector? • No Connect the thermistor connector property. • Yes Is the heater of the fusing unit turned on (when the heater is turned on, light is emitted)? • Yes Check the thermistor connector or replace the main control board or the fusing unit. • No Is the AC voltage being supplied to the connector for the heater of the power supply board? • No Replace the main control board or the power supply board. • Yes Check the heater connector cord and the heater connector for poor contact .