Description: Error detected by toner sensor. (163=K) This error does not occur with the factory default settings.
Remedy: Is toner cartridge setting? Is toner lock lever setting? Does error reoccur? Set toner cartridge. Turn a lock lever of toner to a fixed position. Replace toner sensor or assembly.
Description: An abnormality was detected with the power supply temperature thermistor. 01: Short 02: Open 03: High temp. 04: Low temp.
Remedy: 01, 02: Does error reoccur? Does error reoccur? Does error reoccur? 03: Does error reoccur? Does error reoccur? Does error reoccur? 04: Does error reoccur? Does error reoccur? Does error reoccur? Power Off/On. Replace the low voltage power supply unit. Replace the PU/ CU board. Replace the cable between the low voltage power supply unit and the PU/CU board. Remove anything obstructing the ventilation slots if any and restore the power. Replace the low voltage power supply unit. Replace the PU/ CU board. Replace the cable between the low voltage power supply unit and the PU/CU board. Raise the room temperature and restore the power. Replace the low voltage power supply unit. Replace the PU/ CU board. Replace the cable between the low voltage power supply unit and the PU/CU board.