Code: 160 ... 163

Display: SERVICE CALL 160:ERROR 163:ERROR
Description: Toner sensor detection error (160=Y, 161=M, 162=C, 163=K). This error does not occur with the printer in the factory shipped configuration.
Remedy: Is the toner cartridge installed? Is the toner slide shutter set?
Install the toner cartridge. Turn it to the fixed position. Turn off and on the printer. Replace the toner sensor assembly.

Code: 167

Display: SERVICE CALL 167:ERROR
Description: Thermistor slope error
Remedy: Does an error message appear? Does the error occur again?
Turn off and on the printer. Turn off and on the printer after leaving it for 30 minutes.

Code: 168

Display: SERVICE CALL 168:ERROR (Note)
Description: Compensation thermistor error
Remedy: Does an error message appear? Does the error occur again?
Turn off and on the printer. Turn off and on the printer after leaving it for 30 minutes.

Code: 170, 171

Display: SERVICE CALL 170:ERROR 171:ERROR (Note)
Description: A fuser thermistor short or open circuit was detected.
Remedy: Does the error occur again? Turn off and on the printer. Replace the fuser unit.

Code: 172

Display: SERVICE CALL 172:ERROR 173:ERROR
Description: A fuser thermistor temperature error (high or low temperature) was detected.
Remedy: Does the error occur again? Does the error occur again?
Turn off and on the printer. Replace the fuser unit. Replace the lowvoltage power supply, and then replace the CU/ PU board when the error occurs again.

Code: 174

Display: SERVICE CALL 174:ERROR
Description: A backup thermistor shot circuit was detected (high temperature)
Remedy: Does the error occur again? Yes Turn off and on the printer. Replace the fuser unit.

Code: 175

Display: SERVICE CALL 175:ERROR (Note)
Description: A backup thermistor open circuit was detected (low temperature)
Remedy: Does the error occur again? Yes Turn off and on the printer. Replace the fuser unit.

Code: 176, 177

Display: SERVICE CALL 176:ERROR 177:ERROR
Description: A backup thermistor temperature error (high or low temperature) was detected.
Remedy: Does the error occur again? Turn off and on the printer. Replace the fuser unit.
Does the error occur again? Replace the lowvoltage power supply.