Code :
- Code: 106
- Display: Service call 106:Error
- Description: Abnormal engine control logic.
- Causes: Does error reoccur?
- Code: 111
- Display: Service call 111:Error
- Description: Detected illegal Duplex Unit.
- Causes: Is Duplex Unit of C5300/C5100 installed?
- Code: 112
- Display: Service call 112:Error
- Description: Detected illegal 2nd Tray.
- Causes: Is 2nd Tray of C5300/C5100 installed?
- Code: 120
- Display: Service call 120: ERROR
- Description: PU unit FAN motor error
- Causes: 1) Is the FAN in the PU unit working? 2) Does the same error occur after replacement of the FAN motor?
- Code: 121
- Display: Service call 121:Error
- Description: High-voltage power supply I/F error.
- Causes: Is cable between PU board and high-voltage power unit connected properly? Is there no improperly connections?
- Code: 122
- Display: Service call 122:Error
- Description: Low-voltage power supply fan error. Low-voltage power supply temperature error.
- Causes: Is fan in low-voltage power supply unit operating? Is fan connector connected properly?
- Code: 123
- Display: Service call 123:Error
- Description: Abnormal environment humidty /Not connected humidity sensor.
- Causes: Does error reoccur?
- Code: 124
- Display: Service call 124:Error
- Description: Abnormal environment temperature.
- Causes: Does error reoccur?