Description: 01: thermistor is detected as shorted 02: thermistor is detected as open 03: thermistor indicates high temperature error 04: thermistor indicates low temperature error
Remedy: Is the error message displayed? Yes Restore the power. Does this error recur? Yes After leaving the printer for 30 minutes, turn on the power again
Description: An abnormal (172: high or 173: low) temperature of the fuser thermistor was detected.
Remedy: Does this error recur? Yes Restore the power. Replace the fuser unit. When the power is restored, the display may change to Service Call 994: Error in some cases.
Description: 01: Error in communication with Port CPU. 02: Error in communication with Driver CPU