Remedy: MJ-1106 Saddle controller PC board (SDL) • Check if the conductor pattern on the saddle controller PC board (SDL) is open circuited or short circuited. • Connector check • Board check
Remedy: Saddle controller PC board (SDL) • Check if the conductor pattern on the saddle controller PC board (SDL) is open circuited or short circuited. • Connector check • Board check
Description: Saddle Stitch Finisher additional folding motor abnormality. The [CB93] error also occurs when the error [EF18] has occurred consecutively for 3 times.
Causes: Additional folding motor Saddle control PC board
Remedy: MJ-1106 Additional folding carrierr • Is there any mechanical problem when the additional folding carrier is moved? • Connector check • Harness check Additional folding motor (M20) • Motor check • Connector check • Harness check Saddle control PC board (SDL) • Connector check (CN18) • Board check
Description: Saddle transport motor abnormality. The [CB94] error also occurs when the error [EAB0] or [EF13] has occurred consecutively for 3 times.
Causes: Saddle transport motor Saddle control PC board
Remedy: MJ-1106 Transport roller • Is there any mechanical problem when the transport rollers are rotated? Saddle transport motor (M16) • Motor check • Connector check • Harness check Saddle control PC board (SDL) • Connector check (CN18) • Board check
Description: Saddle Stitch Finisher stacker motor abnormality. The [CB95] error also occurs when the error [EF16] has occurred consecutively for 3 times.
Causes: Stacker motor Saddle control PC board
Remedy: MJ-1106 Stacker carrier • Is there any mechanical problem when the stacker carrier is moved? Stacker motor (M14) • Motor check • Connector check • Harness check Saddle control PC board (SDL) • Connector check (CN4) • Board check