Các lỗi thường gặp

Code :
  • Code: 001
  • Display: Service Call 001: Error
  • Description: A heavy trouble of the CU substrate (defective substrate or power supply capacity shortage) was detected.
  • Causes: Is the error display reproducible? Is the error display reproducible?
  • Code: 002 ... 007
  • Display: Service Call Power off/on nnn: Fatal Error PC: nnnnnnnn LR: nnnnnnnn FR: nnnnnnnn 002: Erro to 007: Error
  • Description: This stems from a variety of causes.For analyzing causes, record three numbers (called program counting value) indicated below LCD column and a printer firmware version. [Cause] Unmatched print data and printer FW Damaged EEPROM data Defect ROM DIMM or RAM DIMM Defect components etc. of CPU and ASIC Others Keep on an alyzing causes if an error still remains. Above mentioned to are likelihood of causes.
  • Causes: Record three digital numbers below LCD column. Restart with OFF/ON? Does an error occur in a particular print data? Is the error display reproducible? Is the error display reproducible? Is the error display reproducible?
  • Code: 020 ... 024
  • Display: Service Call 020: Error or 024: Error
  • Description: CU ROM Hash Check Error 1
  • Causes: Is the Slot A ROM DIMM mounted properly? Is operations restored by replacing the Slot A ROM DIMM?
  • Code: 025
  • Display: Service Call 025: Error
  • Description: CU Font ROM Hash Error1
  • Causes: Detected a Font ROM_DIMM hash check error. (Japan Model only)
  • Code: 030
  • Display: Service Call 030: Error
  • Description: CU Resident RAM Check Error
  • Causes: Is the error display reproducible?
  • Code: 031
  • Display: Service Call 031: Error
  • Description: CU Slot1 DIMM RAM Check Error
  • Causes: Is the applicable RAM DIMM mounted properly? Is operation restored by replacing the applicable RAM DIMM?
  • Code: 032
  • Display: Service Call 032: Error
  • Description: CU Slot2 DIMM RAM Check Error
  • Causes: Is the applicable RAM DIMM mounted properly? Is operation restored by replacing the applicable RAM DIMM?
  • Code: 036
  • Display: Service Call 036: Error
  • Description: Slot1 RAM Spec error Specification of DIMM in CU RAM slot is unsupported.
  • Causes: Is this a standard RAM DIMM? Is the applicable RAM DIMM difference mounted normal? Is operation restored by replacing the applicable RAM DIMM?
 1 2 3 4 >  Last ›
popup

Số lượng:

Tổng tiền:

Danh mục