Code :
- Code: 106
- Display: Service Call 106: Error
- Description: Error in engine control logic detected at power ON.
- Causes: Does error reoccur?
- Code: 107
- Display: Service Call 107: Error
- Description: Engine ROM check sum error.
- Causes: Does error reoccur? Is error recovered by reloading PU F/W?
- Code: 110 ... 116
- Display: Service Call 110: Error ~ 116: Error 110: Envelope Feeder 111: Duplex unit 112: 2nd Tray 113: 3rd Tray 114: 4th Tray 115: 5th Tray 116: Finisher
- Description: Option unit for different model detected.
- Causes: Is a proper option unit for the printer set?
- Code: 120
- Display: Service Call 120: Error
- Description: PU unit fan motor error.
- Causes: 1) Is fan in PU unit operating? 2) Error reoccurs after replacing fan motor.
- Code: 121
- Display: Service Call 121: Error
- Description: High-voltage power supply I/F error.
- Causes: Is cable between PU board andhighvoltage power LSI connected properly?
- Code: 122
- Display: Service Call 122: Error
- Description: Low-voltage power supply fan error. Low-voltage power supply temperature error.
- Causes: 1) Is fan in low-voltage power supply unit operating? 2) Error reoccurs after replacing fan motor
- Code: 123
- Display: Service Call 123: Error
- Description: Improper environment humidity detected by sensor.
- Causes: 1) Is error message displayed? 2) Does error reoccur?
- Code: 124
- Display: Service Call 124: Error
- Description: Improper environment temperature detected by sensor.
- Causes: 1) Is error message displayed? 2) Does error reoccur?