Description: TAG interface error IA TAG interface error was detected. 01 : A short-circuit error. 02 : TAG communication error.
Remedy: Be sure the toner cartridges and the image drums are properly set. Replace the toner cartridges. When the error occurs again after the image drums are re-installed, be sure of the cable connection from the CU/PU board to the toner sensor board.
Remedy: Does the error occur again? Yes Turn off and on the MFP. Replace the SU board
Code: 811, 812, 813
Display: PRESS POWER SW FOR 5SEC Error : 811 Error : 812 Error : 813
Description: SU Communication Error Communication error between the Controller and the Scanner Unit is detected.
Remedy: Communication error between the Controller and the Scanner Unit is detected. Turn off and on the MFP.
Code: 814
Display: PRESS POWER SW FOR 5SEC Error : 814
Description: SU FW Removed It is an error to notify that SU FW was erased by special key operation from a panel.
Remedy: It is an error to notify that SU FW was erased by special key operation from a panel.
Code: 890
Display: PRESS POWER SW FOR 5SEC Error : 890
Description: SU System Memory Overflow
Remedy: Does the error occur again? Yes Turn off and on the MFP. Replace the SU board
Code: 899
Display: Power OFF/ON Error : 899
Description: CU Disconnect
Remedy: In the situation that communication between CU and SU was able to establish, SU FW detected that CU FW had disappeared from a communications path (an USB line).