Description: High-voltage power supply interface error
Remedy: Is the cable between the CU/ PU board and the highvoltage power unit connected properly? Is a contact faulty? Reconnect it properly. Check the highvoltage line for no poor connection. Replace the highvoltage power supply.
Remedy: Does the fan at the rear of the SFP operate? Is the connector of the fan connected properly? Be sure of the connection of the fan. Replace the CU/PU board. Connect the fan properly. Replace the CU/PU board.
Remedy: Is the connector of the fan connected properly? Does the error occur again? Re-connect it properly. Replace the fan motor. Replace the CU/PU board.
Remedy: Is the LED head installed properly? Is the LED head fuse broken? Does the error occur again? Install the LED head unit. Check the LED head fuse. Check the fuse. Turn off and on the SFP. Replace the LED head unit.