Mã lỗi OKI ES5460MFP — Trang 6/9
Code:
Tất cả lỗi (65)
-
-
-
-
-
001
002 ... 007
020
025
030
031
036
040
041
042, 043, 045
051
052
070
072
073
074, 075
081
104
105
106
111
112
120
121
122
123
124
126
127
131 ... 134
140 ... 142
150 ... 153
154
155
160 ... 163
167
168
169
170, 171
172, 173
174
175
176, 177
181, 182
190
200 ... 202
203 ... 214
209
220
230
231
250
251
901, 902
903, 904
918
923
928
980
F0C, FFF, F0D
Display: Service call 167:Error
Description: Thermistor Slope Error
Remedy: Is an error message indicated? Is the error issued again? Turn on the power again. Leave the printer as is for 30 minutes, and turn on the power again.
Display: Service call 168:Error
Description: Compensation Thermistor Error
Remedy: Is an error message indicated? Is the error issued again? Turn on the power again. Leave the printer as is for 30 minutes, and turn on the power again.
Display: Service call 169:Error
Description: Upper Side Thermistor Error
Remedy: Is an error message indicated? Is the error issued again? Turn on the power again. Leave the printer as is for 30 minutes, and turn on the power again.
Display: Service call 170:Error 171:Error
Description: Short circuit in fuser thermistor or open circuit detected.
Remedy: Does error reoccur? Yes Turn power ON again. Replace fuser unit.
Display: Service call 172:Error 173:Error
Description: Abnormal temperature detected by fuser thermistor (high temp or low temp.)
Remedy: Does error reoccur? Yes Turn power ON again. Replace fuser unit.
Display: Service call 174:Error
Description: Short circuit in back up roller thermistor detected (at high temperature).
Remedy: Does error reoccur? Yes Turn power ON again. Replace fuser unit.
Display: Service call 175:Error
Description: Open of back up roller thermistor detected (at low temperature).
Remedy: Does error reoccur? Yes Turn power ON again. Replace fuser unit.
Display: Service call 176:Error 177:Error
Description: Abnormal (high) temperature of back up roller thermistor detected.
Remedy: Does error reoccur? Yes Turn power ON again. Replace fuser unit.