Remedy: Is an error message indicated? Is the error issued again? Turn on the power again. Leave the printer as is for 30 minutes, and turn on the power again.
Code: 168
Display: Service call 168:Error
Description: Compensation Thermistor Error
Remedy: Is an error message indicated? Is the error issued again? Turn on the power again. Leave the printer as is for 30 minutes, and turn on the power again.
Code: 169
Display: Service call 169:Error
Description: Upper Side Thermistor Error
Remedy: Is an error message indicated? Is the error issued again? Turn on the power again. Leave the printer as is for 30 minutes, and turn on the power again.
Code: 170, 171
Display: Service call 170:Error 171:Error
Description: Short circuit in fuser thermistor or open circuit detected.
Remedy: Does error reoccur? Yes Turn power ON again. Replace fuser unit.
Code: 172, 173
Display: Service call 172:Error 173:Error
Description: Abnormal temperature detected by fuser thermistor (high temp or low temp.)
Remedy: Does error reoccur? Yes Turn power ON again. Replace fuser unit.
Code: 174
Display: Service call 174:Error
Description: Short circuit in back up roller thermistor detected (at high temperature).
Remedy: Does error reoccur? Yes Turn power ON again. Replace fuser unit.
Code: 175
Display: Service call 175:Error
Description: Open of back up roller thermistor detected (at low temperature).
Remedy: Does error reoccur? Yes Turn power ON again. Replace fuser unit.
Code: 176, 177
Display: Service call 176:Error 177:Error
Description: Abnormal (high) temperature of back up roller thermistor detected.
Remedy: Does error reoccur? Yes Turn power ON again. Replace fuser unit.