Description: PostScript error Error is deteced inside the postscript core
Remedy: Take note of the address that is displayed on LCD. Turn off and on the MFP.
Code: 072
Description: Engine interface error or CU-PU interface error
Remedy: Is the CU/PU board installed properly? Reinstall the CU/ PU board properly. Replace the CU/ PU board.
Code: 073
Description: Video error. An error was detected in expanding image data (an invalid data was received)
Remedy: Is the CU/PU board installed properly? Does the error occur again? Reinstall it properly. Change the PC to a high-specification one or decrease the resolution, and perform printing again. Replace the CU/ PU board. Replace the interface cable. Reinstall the PC printer driver. Is the CU/PU board installed properly? Does the error occur again? Does the error depend on print data? Reinstall it properly. Perform printing again. Print other data. Replace the CU/PU board. Ask design people to analyze the data.
Code: 074, 075
Description: Video error. An error was detected in expanding image data.
Remedy: Is the CU/PU installed properly? Reinstall it properly. Replace it.
Code: 081
Description: Parameter matching check error Reading from or writing into EEPROM or flash memory cannot be made properly.
Remedy: Reading from or writing into EEPROM or flash memory cannot be made properly. Turn off and on the MFP. Replace the CU/ PU board when the symptom persists.
Code: 104
Description: An engine EEPROM read/write error was detected.
Remedy: Does the error occur again? Yes Turn off and on the MFP Replace the CU/PU board.