Mã lỗi OKI ES7170MFP — Trang 3/15
Description: Compensation Thermistor Error
Causes: Is the error message displayed? Does this error recur?
Remedy: Turn on the power again. After leaving a printer for 30 minutes, turn on the power again.
Description: The fuser thermistor has detected an abnormal temperature (high temperature or low temperature.)
Causes: Does this error recur?
Remedy: Turn on the power again. Replace the fuser unit. Replace the low voltage power supply unit.
Description: Thermistor Slope Error
Causes: Is the error message displayed? Does this error recur?
Remedy: Turn on the power again. After leaving a printer for 30 minutes, turn on the power again.
Description: The backup roller thermistor has detected an abnormal temperature (high temperature or low temperature.)
Causes: Does this error recur?
Remedy: Turn on the power again. Replace the fuser unit. Replace the low voltage power supply unit.
Description: Compensation Heater Temp high Compensation Heater Temp Low
Causes:
Remedy: Turn on the power,after 30min.
Description: Power Supply Thermistor Short Error. (When temperature is high)
Causes:
Remedy: Turn off the Power of the printer and back on.
Description: Power Supply Thermistor Open Error (When temperature is low)
Causes:
Remedy: Turn off the Power of the printer and back on.
Description: Power Supply Thermistor Temp High
Causes:
Remedy: Turn off the Power of the printer and back on.