Description: The belt thermistor detected abnormal (too high or too low) temperature.
Remedy: Is the belt thermistor cable connected properly? Does this error recur? Re-connect the cable properly and restore the power. Replace the belt thermistor, after a lapse of 30 minutes, turn on the power.
Code: 918
Display: Power off/on 918: Error
Description: Duplex FAN error
Remedy: Does this error recur after power restoration? Does this error recur after power restoration? Does this error recur after power restoration? Check if the duplex unit is installed properly. Check if the FAN is connected properly. Replace the FAN.
Code: 923
Display: Power off/on 923: Error
Description: The ID motor is not running normally.
Remedy: Does this error message reappear after power restoration? Does this error message reappear after power restoration? Check if the image drum is installed properly. Replace the image drum unit. Replace the ID motor.
Code: 928
Display: Power off/on 928: Error
Description: The fuser motor is not running normally.
Remedy: Does this error message reappear after power restoration? Does this error message reappear after power restoration? Check if the fuser is installed properly. Replace the fuser. Replace the fuser motor.
Code: 931
Display: Power off/on 931: Error
Description: Duplex unit CPU clock frequency error
Remedy: Does this error message reappear after power restoration? Does this error message reappear after power restoration? Replace the unit. Replace the CU/ PU board.
Code: 933
Display: Power off/on 933: Error
Description: Tray 2 CPU clock frequency error
Remedy: Does this error message reappear after power restoration? Does this error message reappear after power restoration? Replace the unit. Replace the CU/ PU board.
Code: 934
Display: Power off/on 934: Error
Description: Tray 3 CPU clock frequency error
Remedy: Does this error message reappear after power restoration? Does this error message reappear after power restoration? Replace the unit. Replace the CU/ PU board.
Code: 935
Display: Power off/on 935: Error
Description: Tray 4 CPU clock frequency error
Remedy: Does this error message reappear after power restoration? Does this error message reappear after power restoration? Replace the unit. Replace the CU/ PU board.