Remedy: MJ-1106 Saddle control PC board • Update the firmware version of the saddle control PC board (SDL). • Connector check • Board check
Code: CB84
Description: Punch unit main program error
Causes: Hole punch control PC board
Remedy: Hole punch control PC board (HP) • Is the firmware version of the PNC board (HP) latest? • Connector check • Board check
Code: CB91
Description: Saddle flash ROM abnormality
Causes: Saddle controller PC board
Remedy: MJ-1106 Saddle controller PC board (SDL) • Check if the conductor pattern on the saddle controller PC board (SDL) is open circuited or short circuited. • Connector check • Board check
Remedy: Saddle controller PC board (SDL) • Check if the conductor pattern on the saddle controller PC board (SDL) is open circuited or short circuited. • Connector check • Board check
Code: CB93
Description: Saddle Stitch Finisher additional folding motor abnormality. The [CB93] error also occurs when the error [EF18] has occurred consecutively for 3 times.
Causes: Additional folding motor Saddle control PC board
Remedy: MJ-1106 Additional folding carrierr • Is there any mechanical problem when the additional folding carrier is moved? • Connector check • Harness check Additional folding motor (M20) • Motor check • Connector check • Harness check Saddle control PC board (SDL) • Connector check (CN18) • Board check
Code: CB94
Description: Saddle transport motor abnormality. The [CB94] error also occurs when the error [EAB0] or [EF13] has occurred consecutively for 3 times.
Causes: Saddle transport motor Saddle control PC board
Remedy: MJ-1106 Transport roller • Is there any mechanical problem when the transport rollers are rotated? Saddle transport motor (M16) • Motor check • Connector check • Harness check Saddle control PC board (SDL) • Connector check (CN18) • Board check
Code: CB95
Description: Saddle Stitch Finisher stacker motor abnormality. The [CB95] error also occurs when the error [EF16] has occurred consecutively for 3 times.
Causes: Stacker motor Saddle control PC board
Remedy: MJ-1106 Stacker carrier • Is there any mechanical problem when the stacker carrier is moved? Stacker motor (M14) • Motor check • Connector check • Harness check Saddle control PC board (SDL) • Connector check (CN4) • Board check
Code: CBA0
Description: Front saddle stapler home position error
Causes: Front saddle stapler clinch unit Saddle control PC board
Remedy: MJ-1106 Front saddle stapler clinch unit Harness check Saddle control PC board (SDL) • Connector check (CN4) • Board check