Description: An unexpected error occurred during initialization of the Security mode. Error cause information is displayed after the error code number.
Remedy: Power OFF/ON. Does this error message reappear? Yes Regenerate an encryption key. If it doesn’t solve the problem, replace the CU PCB.
Description: Short circuit (901) or open circuit (902) with the belt thermistor was detected.
Remedy: Check the belt thermistor wiring. (Is there any abnormal condition with the belt unit, contact substrate which is the tag terminal PCB of the printer unit, or the cable)? Yes Replace the part or the belt unit. No Replace the driver relay PCB.
Description: The belt thermistor detected abnormal temperature. 903:too high 904:too low
Remedy: Check the belt thermistor wiring. (Is there any abnormal condition with the belt unit, contact substrate which is the tag terminal PCB of the printer unit, or the cable)? Yes Replace the part or the belt unit. No Replace the driver relay PCB.
Description: An error was detected with the paper thickness sensor power cable
Remedy: Power OFF/ON. Does this error recur? Yes Replace the paper thickness sensor and the cable. Does this error recur? Yes Replace the printer control PCB.