Code: 170, 171

Display: Inspection is required.
170 : Error
171 : Error
Description: A fuser thermistor short or open circuit was detected.
Remedy: Does the error occur again? Yes Turn off and on the MFP. Replace the fuser unit.

Code: 172, 173

Display: Inspection is required.
172 : Error
173 : Error
Description: A fuser thermistor temperature error (high or low temperature) was detected.
Remedy: Does the error occur again? Turn off and on the MFP. Replace the fuser unit. Replace the lowvoltage power supply, and then replace the CU/PU board when the error occurs again.

Code: 182

Display: Inspection is required.
182 : Error
Description: Option unit I/F error
Remedy: Does the error occur again? Turn off and on the MFP. Be sure of connector connection. Replace the option unit.

Code: 190

Display: Power OFF/ON
190 : Error
Description: System memory overflow
Remedy: Does the error occur again? Yes Turn off and on the MFP. Replace the CU/PU board.

Code: 200, 201, 202

Display: Inspection is required.
200 : Error
202 : Error
Description: PU firmware download error
An error occurred in rewriting the PU firmware.
Remedy: An error occurred in rewriting the PU firmware. Turn off and on the MFP, and then redownload it (In general use of the MFP, this re-writing is not performed and this error does not occur).

Code: 203, 204, 207, 208

Display: Power OFF/ON
203 : Error
204 : Error
207 : Error
208 : Error
213 : Error
F0C : Error
FFE : Error
FFF : Error
Description: CU program error (203 to 213 do not occur in general use of the MFP)
Invalid processing was performed with a CU program.
Remedy: Invalid processing was performed with a CU program. Replace the CU/PU board.

Code: 209

Display: Power OFF/ON
209 : Download error
Description: Custom Media Type table downloading failure
Custom Media Type table downloading failed.
Remedy: Custom Media Type table downloading failed. Turn off and on the MFP, and then redownload it (In general use of the MFP, this downloading is not performed and this error does not occur).

Code: 213, F0C, FFE, FFF

Display: Power OFF/ON
203 : Error
204 : Error
207 : Error
208 : Error
213 : Error
F0C : Error
FFE : Error
FFF : Error
Description: CU program error (203 to 213 do not occur in general use of the MFP)
Invalid processing was performed with a CU program.
Remedy: Invalid processing was performed with a CU program. Replace the CU/PU board.