Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi OKI MB461 plus LP — Trang 4/7

Code: 123

Display: Inspection is required.
123 : Error
Description: Ambient humidity error or non connection of humidity sensor
Remedy: Is the cable from the CU/PU board to the toner sensor board connected properly?
Re-connect it properly. Replace the toner sensor board.

Code: 124

Display: Inspection is required.
124 : Error
Description: Ambient temperature error
Remedy: Is the cable from the CU/PU board to the toner sensor board connected properly?
Re-connect it properly. Replace the toner sensor board.

Code: 127

Display: Inspection is required.
127 : Error
Description: An error of exhaust fan of the Fuser
Remedy: Is the fan's connector properly connected? Does the error occur again?
Connect properly. Replace the fan's motor. Replace the PU board.

Code: 128

Display: Inspection is required. 128 : Error 05
Description: Image drum fan error
Remedy: Is the connector of the fan connected properly? Does the error occur again?
Re-connect it properly. Replace the fan motor. Replace the CU/PU board.

Code: 134

Display: Inspection is required.
134 : Error
Description: LED head detection error (134=K)
Remedy: Is the LED head installed properly? Is the LED head fuse broken? Does the error occur again?
Install the LED head unit. Check the LED head fuse. Check the fuse. Turn off and on the MFP. Replace the LED head unit.

Code: 153

Display: Inspection is required.
153 : Error
Description: Image drum unit fuse-cut error
Remedy: Is the image drum unit installed properly? Does the error occur again? Is the MFP recovered by replacing the toner sensor board.
Re-install it. Turn off and on the MFP. Be sure of the cable connection from the CU/PU board to the toner sensor board, and then replace the toner sensor board. Replace the CU/PU board.

Code: 163

Display: Inspection is required.
163 : Error
Description: Toner sensor detection error (163=K). This error does not occur with the MFP in the factory shipped configuration.
Remedy: Is the toner cartridge installed? Is the toner slide shutter set?
Install the toner cartridge. Turn it to the fixed position. Turn off and on the MFP. Replace the toner sensor assembly.

Code: 167

Display: Inspection is required.
167 : Error
Description: Thermistor slope error
Remedy: Does an error message appear? Does the error occur again? Yes Turn off and on the MFP. Turn off and on the MFP after leaving it for 30 minutes.