Code: 105

Display: Service call
105: Error
Description: Engine EEPROM mounting check error when the power supply is turned on.
Remedy: Does the error recur? Yes Power supply Off/On Replace 86M board

Code: 106

Display: Service call
106: Error
Description: The engine control logic is abnormal
Remedy: Does the error recur? Yes Power supply Off/On Replace 86M board

Code: 120

Display: Service call
120: Error
Description: 86M Board Fan Motor Error
Remedy: Does the fan rotate? • Yes Replace the main board. • No Is the fan connector of the high-voltage power/ sensor board connected? • No Connect the fan connector appropriately. • Yes Does F3-fuse of 86M board open? • Yes Change the F3-fuse. • Yes Replace the fan or main board.

Code: 121

Display: Service call
121: Error
Description: High-voltage power supply I/F error
Remedy: Is the cable between 86M board and the high-voltage power supply unit correctly connected? Isn't there defective contact point?
Reconnect correctly. Check the defective contact point of high-voltage system. Replace the high voltage power supply.

Code: 122

Display: Service call
122: Error
Description: Power Supply Fan Motor Error
Remedy:

Code: 123

Display: Service call
123: Error
Description: Environmental humidity abnormal/ humidity sensor disconnection
Remedy: Is the cable between the 86M board and the high-voltage power supply unit correctly connected?
Reconnect correctly. Replace the high-voltage power supply.

Code: 124

Display: Service call
124: Error
Description: Environmental temperature abnormality
Remedy: Does the error recur? Yes Power supply Off/On Check the connector connection of Thermistor. Replace Thermistor or 86M board.

Code: 126

Display: Service call
126: Error
Description: The dewy of the device is detected
Dew condensation occurs easily after the device is carried in from outside.
After leaving it at room temperature for 2 hours to half a day, turn on the power again.
Remedy: Dew condensation occurs easily after the device is carried in from outside. After leaving it at room temperature for 2 hours to half a day, turn on the power again. Does the error recur? Yes Turn on the power again after leaving the device for hours. Replace the high-voltage power supply.