Code: 112

Display: Inspection is required. 112 : Error
Description: The 2nd tray for a model different from the MFP was detected.
Causes: Is the 2nd tray for the MFP installed?

Code: 121

Display: Inspection is required. 121 : Error
Description: High-voltage power supply interface error
Causes: Is the cable between the CU/ PU board and the highvoltage power unit connected properly? Is a contact faulty?

Code: 122

Display: Inspection is required. 122 : Error
Description: Power Supply Fan error
Causes: Does the fan at the rear of the MFP operate? Is the connector of the fan connected properly?

Code: 123

Display: Inspection is required. 123 : Error
Description: Ambient humidity error or non connection of humidity sensor
Causes: Is the cable from the CU/PU board to the toner sensor board connected properly?

Code: 124

Display: Inspection is required. 124 : Error
Description: Ambient temperature error
Causes: Is the cable from the CU/PU board to the toner sensor board connected properly?

Code: 126

Display: Power OFF/ON 126 : Error
Description: Sensor Dewed Error
Causes:

Code: 127

Display: Inspection is required. 127 : Error
Description: An error of exhaust fan of the Fuser
Causes: Is the fan's connector properly connected? Does the error occur again?

Code: 128

Display: Inspection is required. 128 : Error 05
Description: Image drum fan error
Causes: Is the connector of the fan connected properly? Does the error occur again?