Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi OKI MB770 — Trang 6/15

Code: C91E

Description: When separate toner is setting, occur the error in case the ID and TC is same Tag.
Causes:
Remedy: Set the correct tag in ID and TC.

Code: C91F

Description: Detect to receive the each color. Change the ERR04
Causes:
Remedy: Set the correct tag in ID and TC.

Code: C921

Description: AC voltage zero-crossing error
Causes:
Remedy: Check the AC voltage. Change the Lowvoltage board or PU board.

Code: C940

Description: Engine control logic has an error.
Causes: Does this error recur?
Remedy: Turn off the power of the printer and back on. Replace the PU board.

Code: C96A

Description: High voltage power supply interface error
Causes: Is the cable connecting the PU board to the high voltage unit connected normally? Have you checked defective contact of contactor points?
Remedy: Re-connect them normally. Check for defective contact of the high voltage system. Replace the high voltage power supply.

Code: C9A0

Description: Offline stapler error
Causes:
Remedy: Change the offline stapler

Code: CE50

Description: Environment temperature is abnormal.
Causes: Does this error recur?
Remedy: Turn off the power of the printer and back on. Replace the Board 8TH.

Code: CE51

Description: Environment humidity is abnormal./ Humidity sensor is not connected.
Causes: Does this error recur?
Remedy: Turn off the power of the printer and back on. Replace the Board 8TH.