Code: 001

Display: Inspection is required. 001 : Error
Description: Machine Check Exception
A hardware error was detected (board failure or insufficient power supply capacity).
Remedy: Replace the CU/ PU board.

Code: 002, 006, 009, 011

Display: Power OFF/ON 002 : Error 006 : Error 009 : Error 011 : Error
Description: CPU Exception
Remedy: Is the error display provided again?
Remove any RAM DIMM and turn off and on the MFP. Replace the CU/ PU board. Reinstall the RAM DIMM.

Code: 020

Display: Inspection is required. 020 : Error
Description: CU ROM Hash Check Error
Remedy: Is the error display provided again? Yes Turn off and on the MFP. Replace the CU/ PU board.

Code: 024, 025

Display: Inspection is required. 024 : Error 025 : Error
Description: Kanji Font Error
Remedy:

Code: 030

Display: Inspection is required. 030 : Error
Description: CU RAM Check Error
Remedy: Is the error display provided again? Yes Turn off and on the MFP. Replace the CU/ PU board.

Code: 031, 036

Display: Inspection is required. 031 : Error 036 : Error
Description: CU optional RAM check error
Remedy: Is RAM DIMM installed properly? Does the MFP recover by replacing the RAM DIMM?
Reinstall the RAM DIMM. Replace the RAM DIMM. Replace the CU/ PU board.

Code: 040

Display: Inspection is required. 040 : Error
Description: CU EEPROM error
Remedy: Is the error display provided again? Yes Turn off and on the MFP. Replace the CU/ PU board.

Code: 041

Display: Inspection is required. 041 : Error
Description: CU flash memory error or CU board flash ROM error
Remedy: Is the error display provided again? Yes Turn off and on the MFP. Replace the CU/ PU board.