Code: 907

Display: Service call 907: Error
Description: High temperature error of the frame thermistor (over 150)is detected
Remedy: Does the error recur? Yes Check the cable connection between the ZAK board and M32 board and turn on the power again.Replace the fuser unit. Replace the M32 board.

Code: 908

Display: Service call 908: Error
Description: Low temperature error of the Frame thermistor (lower than [environment temperature -10]) is detected
Remedy: Does the error recur? Yes Check the cable connection between the ZAK board and M32 board and turn on the power again. Replace the fuser unit. Replace the M32 board.

Code: 923

Display: 923: Error
Description: Image Drum Lock Error
Remedy: The ID motor does not rotate correctly. Is the error message displayed when the power is turned on again?
Check if the ID unit is set correctly. Replace the ID unit. Replace the ID motor.

Code: 980

Display: Service call 980: Error
Description: Media coiling error to the fuser
Media is coiled to the fuser
Remedy: Media is coiled to the fuser Turn off the power supply. Replace the fuser.

Code: 981

Display: Service call 981: Error
Description: Difference between PU model version detected and CU model version detected
High-voltage power supply I/F error when initializing
PU board SRAM error
CRC check error of PU download data
PU board Flash ROM hash check error
PU board Flash ROM writing error
The communication error with ASIC on the CU board is detected
Remedy: Does the error recur? Yes Turn off/on the power supply. Replace the M32 board.
Is the cable between PU board and the high-voltage power supply unit correctly connected? Isn’t there defective contact point?
Reconnect correctly.Check the defective contact point of highvoltage system. Replace the high voltage power supply.
Does the error recur? Yes Turn off the power supply again Replace the M32 board
After PU data is downloaded (PU fireware, custom media data, head correction data), CRC check error is detected. After the power supply is turned on again, try to download again. (Because this processing is not performed during usual operation, it does not occur.)
Does the error recur? Yes Turn on the power supply again Replace the M32 board
Does the error recur? fter the power supply is turned on again, try to download again. (Because this processing is not performed during usual operation, it does not occur.)
The communication error with ASIC on the CU board is detected. Replace the M32 board.

Code: F0C, FFE, FFF

Display: Service call 203: Error 204: Error 207: Error 208: Error 213: Error 214: Error F0C: Error FFE: Error FFF: Error
Description: CU program trouble (203~214 are not generated in usual operation)
Remedy: Incorrect processing is performed by the CU program. Does the error recur? Turn on the power supply again. Replace M32 board.