Mã lỗi OKI MC873dn — Trang 5/14
Display: Inspection is required. 105:Error
Description: Not detect the EEPROM at power on
Causes:
Display: Inspection is required. 106:Error
Description: Detect the error at engine control logic
Causes:
Display: Inspection is required. 111:Error
Description: A duplex unit for another model was detected
Causes: Is a duplex unit provided for this model installed?
Display: Inspection is required. 112:Error
Description: A Tray2 for another model was detected
Causes: Is a Tray2 provided for this model installed?
Display: Inspection is required. 113:Error
Description: A Tray3 for another model was detected.
Causes: Is a Tray3 provided for this model installed?
Display: Inspection is required. 114:Error
Description: A Tray4 for another model was detected.
Causes: Is a Tray4 provided for this model installed?
Display: Inspection is required. 120:Error
Description: PU cooling FAN error
Causes: Is the FAN connector connected correctly?
Display: Inspection is required. 121:Error
Description: High voltage power supply interface error
Causes: Is the cable connecting the CU board to the high voltage power supply unit connected properly? Is there any defective contact point?