Description: CU Disconnect In the situation that communication between CU and SU was able to establish, SU FW detected that CU FW had disappeared from a communications path (an USB line).
Remedy: Is the cable from the belt thermistor to the CU/PU board connected properly? Does the error occur again? Connect the cable properly. Turn off and on the MFP. Replace the belt thermistor.
Code: 901 ... 904
Description: Belt temperature error 901: Short circuit 902: Open circuit 903: High temperature 904: Low temperature
Remedy: Is the cable from the belt thermistor to the CU/PU board connected properly? Does the error occur again? Connect the cable properly. Turn off and on the MFP. Replace the belt thermistor.
Code: 918
Description: An alarm of Duplex Fan was detected.
Remedy: An error of a fan inside the Duplex. Is it reproduced by turning on thepower unit? Review whether or not the Duplex is installed properly. Review whether or not the fan is installed properly. Replace the fan.
Code: 923
Description: A lock error with black image drum The image drum does not revolve properly.
Remedy: The image drum does not revolve properly. Does the error display is provided again by turning off and on the MFP? Be sure the image drum is properly installed properly. Replace the image drum unit. Replace the image drum motor.
Code: 928
Description: Fuser motor lock error
Remedy: The fuser does not operate properly? Does the error occur again? Check that the fuser is properly installed. Replace the fuser. Replace the fuser motor.
Code: 933
Description: Tray-2 CPU clock frequency error
Remedy:
Code: 941, 942, 943, 944
Description: PU Error A PU error was detected. 941 : Watch Doc Timer Error 942 : Detection of Unassigned Interruption 943 : CPU Error Detection 944 : Dcon Access Error
Remedy: Turn off and on the MFP. When this error occurs again, replace the CU/ PU board.
Code: 980