Description: Duplex FAN0 Alarm Detection Error of the fan in the duplex unit
Remedy: Error of the fan in the duplex unit Does the error still occur after rebooting? Check to confirm that the duplex unit is mounted correctly. Check the connection of the fan. Replace the fan.
Code: 919
Display: Power Off/on 919: Error
Description: Duplex 24V Abnormal Current Detection 24 V of power is not supplied to the duplex unit properly.
Remedy: 24 V of power is not supplied to the duplex unit properly. Does the error still occur after rebooting? Check to confirm that the duplex unit is mounted correctly. Check the connection of the fan. Replace the fan.
Code: 920
Display: Power Off/on 920: Error
Description: Yellow Image Drum Lock Error. The Y ID unit is not operating properly.
Remedy: The Y ID unit is not operating properly. Does the error message still appear after rebooting? Check to confirm that the Y ID unit is in position. Replace the Y ID unit. Replace the Y ID motor.
Code: 921
Display: Power Off/on 921: Error
Description: Magenta Image Drum Lock Error. The M ID unit is not operating properly.
Remedy: The M ID unit is not operating properly. Does the error message still appear after rebooting? Check to confirm that the M ID unit is in position. Replace the M ID unit. Replace the M ID motor.
Code: 922
Display: Power Off/on 922: Error
Description: Cyan Image Drum Lock Error. The C ID unit is not operating properly.
Remedy: The C ID unit is not operating properly. Does the error message still appear after rebooting? Check to confirm that the C ID unit is in position. Replace the C ID unit. Replace the C ID motor.
Code: 923
Display: Power Off/on 923: Error
Description: Black Image Drum Lock Error. The K ID unit is not operating properly.
Remedy: The K ID unit is not operating properly. Does the error message still appear after rebooting? Check to confirm that the K ID unit is in position. Replace the K ID unit. Replace the K ID motor.
Code: 924
Display: Power Off/on 924: Error
Description: Tray2 24V Abnormal Voltage Detection 24 V of power is not supplied to tray 2 properly.
Remedy: 24 V of power is not supplied to tray 2 properly. Check to confirm that tray 2 is mounted correctly.
Code: 925
Display: Power Off/on 925: Error
Description: Tray3 24V Abnormal Voltage Detection 24 V of power is not supplied to tray 3 properly.
Remedy: 24 V of power is not supplied to tray 3 properly. Check to confirm that tray 3 is mounted correctly.