Remedy: The fuser is not operating properly. Does the error still occur? Yes Check to confirm that fuser is in position. Replace fuser Yes Replace the fuser motor.
Description: Waste Toner Transfer Motor Lock Error
Remedy: The waste toner transfer motor is not operating properly. Does the error still occur? Yes Check to confirm that the waste toner transfer system is operating properly. Replace waste toner motor
Remedy: The duplex CPU clock frequency is not correct. Does the error still occur? Yes Check the connection of the V72-18 board. Replace the V72-18 board.
Remedy: The inverter CPU clock frequency is not correct. Does the error still occur? Yes Check the connection of the V72-13 board. Replace the V72-13 board.
Remedy: The transfer mechanism of the toner duct for ID is not operating properly. Does the error still occur? Check to confirm that the basket assembly is in position (if it is engaged with the gear of the printer). Yes Check to confirm that the holder magnet D contains a magnet, and check the magnetic polarity. Yes Replace the HAL IC circuit board. Yes Replace the duct assembly toner.