Code: 200

Description: Decoding process is not completed at the end of phase C.
Causes: Defective SC PCB.

Code: 212

Description: Interface error occurred between the CPU and modem.
Causes: Modem is defective. (SC PCB) Software problem occurred. (SC PCB)

Code: 301

Description: System fault.
Causes: Software problem occurred. (SC PCB)

Code: 331

Description: 8-minutes timer error. (Germany only)
Causes:

Code: 390

Description: Interface error occurred between the machine and the PC.
Causes: Firmware update error. GDI print error. (Perform the operation again)

Code: 400

Description: T1 timer (35±5 sec.) elapsed without detecting 300 bps signal.
Causes: Wrong number is dialed and the START button is pushed. Telephone line is disconnected while dialing. SC PCB (Modem) or MJR PCB are defective. Receiver is defective. (It may only be transmitting CED)

Code: 401

Description: DCN was returned from receiver while transmitter is waiting for CFR or FTT.
Causes: Your machine's ID Number is not programmed. Possible incompatibility or incorrect Password.

Code: 402

Description: DCN was returned from receiver while transmitter is waiting for NSF/DIS.
Causes: Receiver working in non-CCITT mode only. (Possible incompatibility)