Các lỗi thường gặp

Code :
  • Code: 505
  • Description: Polling XMT is rejected.
  • Causes: No polling original is set.
  • Code: 540
  • Description: No response after transmitting 3rd CTC or DCN received.
  • Causes: Incompatible interface.
  • Code: 541
  • Description: No response after transmitting 3rd EOR or received DCN.
  • Causes: Line is faulty. MJR PCB abnormal.
  • Code: 542
  • Description: No response to the 3rd RR transmitted or received DCN.
  • Causes: Remote unit is abnormal.
  • Code: 543
  • Description: T5 timer (60 sec.) elapsed without MCF.
  • Causes: Remote unit is abnormal.
  • Code: 544
  • Description: Stopped Transmission after EOR Transmission.
  • Causes: Line is faulty. MJR PCB abnormal.
  • Code: 550
  • Description: Timer between frames in phase C has elapsed.
  • Causes: Defective remote station.
  • Code: 554
  • Description: Transmitted ERR after receiving EOR.
  • Causes: Line is faulty.