Code :
  • Code: 555
  • Description: Transmitted PIN after receiving EOR.
  • Causes: Line is faulty and Operator Call requested by RX side.
  • Code: 570
  • Description: Password or machine code did not match during remote diagnostic communication.
  • Causes:
  • Code: 571
  • Description: Remote unit did not have the remote diagnostic function.
  • Causes:
  • Code: 580
  • Description: Sub-address transmission to a unit that has their DIS bit 49 (NSF bit 155) OFF.
  • Causes: Sub-address transmission to a unit that has no Sub-address function.
  • Code: 581
  • Description: Sub-address Password transmission to a unit that has their DIS bit 50 (NSF bit 156) OFF.
  • Causes: Sub-address transmission to a unit that has no Sub-address function.
  • Code: 601
  • Description: ADF Door was opened during ADF transmission.
  • Causes:
  • Code: 623
  • Description: No original was in the ADF. (Builtin dialer engaged)
  • Causes: Operator removed the original from the ADF after dialing was completed. Original was not set properly in the ADF.
  • Code: 630
  • Description: Redial count over.
  • Causes: No dial tone detected. Sensor dial tone is not detected. (destination dependent) Busy tone is detected. (destination dependent) T1 timer (35±5 sec.) elapsed without a signal from the receiver.