Các lỗi thường gặp

Code :
  • Code: 421
  • Description: Busy Tone is detected after sending NSF Signal.
  • Causes: Remote station disconnected the line. Wrong number is dialed.
  • Code: 422
  • Description: Content of NSF (or DIS) or NSC (or DTC) was invalid.
  • Causes: There is an incompatibility.
  • Code: 427
  • Description: DCN received to NSF/CSI/DIS transmitted
  • Causes: The interface is incompatible.
  • Code: 433
  • Description: .T.30 Protocol abnormal.
  • Causes: Defective remote station.
  • Code: 434
  • Description: CD (response from Modem) did not turn OFF within 180 sec. after receiver detected FLAG signal.
  • Causes: Remote unit is defective. SC PCB or MJR PCB are defective.
  • Code: 436
  • Description: DCN received after transmitting FTT.
  • Causes: Transmitter is defective or incompatible. Line quality is poor.
  • Code: 456
  • Description: Received relay transfer request or confidential document to distribute to an end receiving station or all confidential mailboxes are used.
  • Causes:
  • Code: 459
  • Description: Failed training in Phase C.
  • Causes: Line quality is poor. (Training signal is distorted due to line noise) SC PCB or MJR PCB are defective.