Các lỗi thường gặp

Code :
  • Code: SC604
  • Description: Communication error between BCU and high voltage control board
    The BCU board cannot communicate with the high voltage control board properly
  • Causes: • Poor connection of the interface harness which connects the BCU baord and the high voltage control baord. • High voltage control board defective
  • Code: SC605
  • Description: Communication error between SCU and BCU
    The SCU board cannot communicate with the BCU board properly.
  • Causes: • Poor connection • SCU board defective • BCU board defective
  • Code: SC620
  • Description: Communication error between BCU and ARDF
    The BCU board cannot start communication with the ARDF properly.
  • Causes: • Poor connection • BCU board defective • DF main board defective
  • Code: SC621
  • Description: Communication error between BCU and finisher
    The BCU board cannot start communication with the finisher properly.
  • Causes: • Poor connection • BCU board defective • Finisher main control board defective
  • Code: SC623
  • Description: Communication error between BCU and paper tray unit
    The BCU board cannot start communication with the paper tray unit properly.
  • Causes: • Poor connection • BCU board defective • Paper tray unit defective
  • Code: SC625
  • Description: GA5 (GAFBTC) Error
    The GA5 did not finish the data transfer to the memory in 20 seconds.
  • Causes:
  • Code: SC720
  • Description: Finisher transport drive motor error
    An abnormal motor condition is detected from the finisher transport drive motor.
  • Causes: • Finisher transport drive motor defective • Finisher main control board defective
  • Code: SC721
  • Description: Finisher tray lift/shift motor error
    An abnormal motor condition is detected from either the finisher tray lift or shift motor.
  • Causes: • Finisher tray lift motor defective • Finisher tray shift motor defective • Finisher main control board defective